Medical Device Moulds Where Documentation Is Part of the Product
A diagnostic housing, a disposable component or a device part is not judged on looks alone. It must be biocompatible, moulded in a controlled room, validated shot after shot, and traceable by lot — because a moulding defect here is a patient risk, not a returns label.
A medical mould is a validated process, not a tool
Medical moulding is a different quality system from commercial moulding. The resin, the room, the press and the paperwork are all part of the product, and none of them changes without a formal re-validation.
We build moulds for diagnostic housings and cartridges, IV connectors, inhaler bodies, syringe components, surgical instrument handles and disposable device parts. This page covers the general medical device range; our syringe, centrifuge tube and pipette tip moulds each have their own page with their own requirements.
Biocompatibility is proven, not claimed. Resins must carry USP Class VI certification, and the fuller ISO 10993 framework governs the risk assessment — USP Class VI alone is not enough for a modern FDA submission. Cleanroom class follows the device risk: ISO Class 7 for diagnostic housings and non-sterile components, ISO Class 8 for external enclosures.
- Diagnostic housings, cartridges and connectors
- USP Class VI and ISO 10993-qualified resins
- ISO Class 7 or 8 cleanroom moulding
- IQ/OQ/PQ validation and lot traceability
Four decisions that decide a medical device mould
Medical parts fail in the audit, not on the shelf. These four details are where audit failures start.
Biocompatible resins
Only certified medical-grade resins are used — PC, PEI, PEEK, PSU, POM, PP and COP/COC. A generic grade that “looks similar” is never substituted without a new certificate.
Cleanroom tooling
Corrosion-resistant steel such as Stavax ESR, grease-free tooling and all-electric presses keep particles and oil mist out of the room. The tool is built to be cleaned and returned to production fast.
Tight, stable tolerances
Fluid paths and mating housings need dimensions that repeat shot after shot. Wall, gate and cooling are set in the DFM review, because a tolerance fix after tooling is cut costs ten times more.
Traceability by lot
Every lot of resin and every shot is recorded, so a field question can be traced back to the exact material batch. Laser-marked UDI and lot codes are built into the tool where the device needs them.
Resins for medical devices
The grade datasheet for your exact resin outranks any general table.
| Material | Where it fits | Watch for |
|---|---|---|
| PC | Diagnostic housings, transparent covers | High impact; needs pre-drying |
| PP / PE | Disposables, fluid-path parts | USP Class VI grades only |
| PEI / PEEK | High-temperature device parts | High cost; check sterilisation method |
| COP / COC | Diagnostic cartridges, optics | Clear; low extractables |
What to send for an accurate mould quote
A complete pack lets us quote without guessing.
| Item | What we need from you |
|---|---|
| 3D model | STEP or IGES file, plus 2D drawing |
| Device class | FDA Class I, II or III — sets validation |
| Contact type | Skin, blood or implant contact |
| Cleanroom needs | ISO Class 7, 8, or controlled room |
| Volume | Annual quantity and batch size |
Questions buyers ask before tooling
Is USP Class VI enough for an FDA submission?
No — it is necessary but not sufficient. The FDA expects an ISO 10993-1 risk-based assessment for 510(k) and PMA submissions, and USP Class VI does not replace it.
Which cleanroom class does my device need?
It follows the risk: ISO Class 7 suits diagnostic housings and non-sterile components, ISO Class 8 suits external enclosures and packaging. Implantables need tighter classes still.
What does IQ/OQ/PQ validation cover?
Installation, operational and performance qualification of the moulding process. For Class II and III devices it is a regulatory requirement under 21 CFR Part 820 and ISO 13485, not an option.
What do you deliver with the mould?
A DFM report, mould-flow analysis where the geometry needs it, steel certificates, T1 samples, and dimensional reports — plus validation documents, lot traceability and resin certificates.
Send the device drawing. We will check it before quoting.
Tell us the device class, the contact type, and the cleanroom it needs.